Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | Standby |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | EA1000-500 | EA1000-650 | EA1000-800 | EA1000-1000 | |
CAPACITY | 500 VA/ 300 W | 650 VA/ 390 W | 800 VA/ 480 W | 1000 VA/ 600 W | |
INPUT | |||||
Voltage | Nominal Voltage | 110/120 VAC or 220/230/240 VAC | |||
Acceptable Voltage Range | 90-145 VAC/150-290 VAC | ||||
Frequency Range | 50 Hz/60HZ | ||||
OUTPUT | |||||
AC Voltage Regulation (Batt. Mode) | ±10% | ||||
Frequency Range (Batt. Mode) | 50 Hz or 60 Hz | ||||
Transfer Time (Typical) | 2-6 ms | ||||
Waveform (Batt. Mode) | Modified Sinewave | ||||
BATTERY | |||||
Battery Type & Numbers | 12 V 7 Ah x 1 | 12 V 7 Ah x 1 | 12 V 9 Ah x 1 | 12 V 7.2 Ah x 2 | |
Back up Time(at a PC load | 8-10 minuters | 8-10 minuters | 15 minuters | 15 minuters | |
Typical Recharge Time | 10 hours to 90% after complete discharge | ||||
INDICATORS | |||||
AC Mode | Green LED lighting | ||||
Battery Mode | Green LED flashing every 4 seconds | ||||
Low Battery at Battery Mode | Green LED flashing every second | ||||
Fault | Red LED lighting | ||||
Battery Fault at AC modes | Green LED flashing three times every 2 seconds | ||||
Battery Week at AC modes | Red LED flashing every 2 seconds for 30 seconds | ||||
Overload | Red LED flashing every twice every second | ||||
ALARM | |||||
Battery Mode | Sounding every 4 seconds | ||||
Low Battery | Sounding every second | ||||
Fault | Continuously sounding | ||||
PHYSICAL | |||||
Dimension, D X W X H (mm) | 295*95*140 | ||||
Net Weight (kgs) | 5.5 | 6.2 | 6.8 | 10.5 | |
ENVIRONMENT | |||||
Humidity | 0 to 90% Relative Humidity(Non-condensing) | ||||
Operating Temperature | 0°Cto 40°C |