Must 3 Phase Low Frequency Online UPS 10k-550kVA Industrial
Features
Low power consumption up to 94%
Cold start directly and smart operation for users.
Simple to install: Capability to install the UPS into any distribution system (neutral not required on rectifier input)
Capability of regulating the output voltage (to offset voltage drops down long cable runs)
Built-in automatic and manual battery test feature, battery deep discharge protection and temperature compensating charger
Back-feed protection: To avoid energy feeding back into the mains supply should a fault occur
Reliable, filtered, stabilized and regulated sine wave output (double conversion on-line technology )with filters for atmospheric
Specifications
MODEL |
EH9115 100KS |
EH9115 120KS |
EH9115 160KS |
CAPACITY |
100KVA/80KW |
120KVA/96KW |
160KVA/128KW |
INPUT |
Voltage |
380/400/415 Vac +/-20%(3 phase and 4 wire) |
Input range |
+/ - 20% ( > +/- 20% is available upon request) |
Input Frequency |
50 / 60 Hz + / - 10% |
Efficiency |
> 93% |
Voltage Regulation |
+ / - 1% |
Phase |
3-Phase Input / 3-Phase Output |
OUTPUT |
AC Voltage Regulation (Batt. Mode) |
380/400/415 Vac +/-1% 380/100/415Vac+/-3% ( 3 phase and 4 wire) |
Frequency Range (Synchronized Range) |
Simulaneoously with line input (Commercial power status) |
Power Factor |
0.8 |
Harmonic Distortion |
<=2 % THD (Linear Load) |
TRANSFER TIME |
AC to DC |
Zero |
Inverter to Bypass |
4 ms (Typical) |
Waveform (Batt. Mode) |
Pure Sine Wave |
BATTERY |
Battery Type & Numbers |
Maintenance free lead-acid batteries / 12V x 32pcs |
Charge |
6-20A |
Current Adc (Selectable) |
Battery Start |
Yes, UPS can be started without AC source. |
INDICATORS |
LCD Panel |
UPS status, Load level, Battery level, Input/Output voltage, and Fault |
conditions |
130% overload |
10 minutes |
130 - 150% overload |
60 seconds |
> 150% overload |
30 seconds |
Efficiency (100% Load) |
0.945 |
PHYSICAL |
Dimension D*W*H(mm) |
1000*900*1680 |
Net Weight(kgs) |
840 |
940 |
1010 |
OPERATING ENVIRONMENT |
Humidity |
0% - 90% (NonLCCondensing) |
Temperature |
0 - 40°C |
Noise Level |
< 65 dBA (At 1 M) |
Altitude |
<1500 M Above Sea Level |
Crest ratio |
3:01 |
Short Circuit Pretection |
YES |
Lightning / EMC Filter |
MOV / Input&Output |
Galvanic Isolation |
Input&Output true Galvanic isolation |
LED,LCD,Buzzer |
YES |
MANAGEMENT |
Remote Control / |
Dry contact, True RS232 port |
Communication Interface |
* Product Specifications are subject to change without further notice. |
Disturbance suppression- high reliability, full microprocessor control with no-break static and manual bypasses, extremely high short-circuit
Current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation
Transformer on the inverter output- maximum reliability and power availability- high level diagnostics: Event log with messages, status,
Measurements and alarms - available from the built-in LCD in several languages
Welcome to contact me freely.