Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | ISO9001, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | 230V Models | ||
OUTPUT | |||
Power Levels crated at nominal inputs | 1KW;2KW;3KW | ||
Output Voltage | 220V/230V/240V Selectable | ||
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:'1 | ||
Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
(Synchronized to Mains) | |||
efficienly(DC mode) | >80% | ||
Surge Rating | 3000VA / 6000VA / 9000VA | ||
Capable of motor | 1kw/2kw: 1HP 3KW:2HP | ||
Transfer time | 10ms typical | ||
protection | Over load protection, battery over voltage & under voltage protection | ||
Oover temperature protection | |||
short circuit protection | |||
INPUT | |||
Nominal Voltage | 220V/230V/240V Selectable | ||
Input Frequency | 40Hz ~ 80Hz, 50/60Hz auto-sensing | ||
Efficiency (line mode) | >95% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Voltage Range | 155Vac-265Vac | ||
Charge current | 65A max. | ||
Inverter main features | huge charge current | ||
pure copper transformer | |||
pure sine wave | |||
supports inductive loads | |||
Surge Protection | 1KW-3KW:430 Joules | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) | |
DC Voltage | 1KW:12Vdc | 2KW:12Vdc | |
2KW:24Vdc | 3KW:12Vdc | ||
3KW:24Vdc | 3KW: 48Vdc | ||
Typical backup time | up to external battery | ||
Charging method | battery charger (bulk, absorption, and float) | ||
charge current is ajustable 25% 50% 75% 100% (optional) | |||
Maximum charging current | 1000W 12V:35A | 2000W 12V:65A | |
2000W 24V:35A | 3000W 12V:65A | ||
3000W 24V:45A | 3000W 48V:25A | ||
Average charging | Quick charging mode:15.7V-54V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V -52V | ||
Protection | Over current protection | ||
Over charging voltage protection | |||
When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate | |||
Monitoring | RS232 communication port | ||
remote control cable 10 meters | |||
SOLAR CHARGER | |||
Rating voltage | 12V / 24V / 48V | ||
DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc | ||
Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) | ||
24V model : 1000W/2000W (27.0Vdc @ 37A) | |||
48V model : 3KW/4KW/5KW/6KW (54Vdc @ 18.5A) | |||
Protection | DC input polarity protection, DC input short circuit protection. | ||
(when battery is connected), DC output over current protection. | |||
COMMUNICATIONS & MANAGEMENT | |||
Control panel | LCD&LED indicators | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVORMENT AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001 | ||
PHYSICAL | |||
Appearance | Size(mm)LxWxH | 570*315*300mm | |
Weight(Kg) | 1000W/19kg ;2000W/24kg ;3000W/28kg |