Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | CCC, ISO9001, RoHS, CE, SAA |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | 115V Models | 230V Models | |
OUTPUT | |||
Power Levels crated at nominal inputs | 1KW;2KW;3KW;4KW | 1KW;2KW;3KW;4KW;5KW;6KW | |
Output Voltage | 110V/115V/120V Selectable | 220V/230V/240V Selectable | |
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:'1 | ||
Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
(Synchronized to Mains) | |||
Regulation (Nominal) | ±20% typical of nominal voltage | ||
Regulation | ±3% of selected output voltage (adjustable with the | ||
(Battery mode) | remote set-up software) | ||
Transfer time | Blackout 3ms typical,Brownout 1ms typical,Battery mode to Normal mode:1ms typical | ||
Over current protection | Over load alarm level 100% ~ 120% | ||
Over load shutdown level 120% ~ 190% | |||
(Adjustable by using the remote set-up software) | |||
INPUT | |||
Nominal Voltage | 110V/115V/120V Selectable | 220V/230V/240V Selectable | |
Input Frequency | 47Hz ~ 65Hz, 50/60Hz auto-sensing | ||
Efficiency (Normal mode) | 99% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Over current protection | Re-settable over current protector:1000W~4KW | AC Fuse1000VA/2000VA,Re-settable over current protector:1000W~6KW | |
Voltage Range | 85V ~ 145V | 185V ~ 265V | |
AVR Range (2 Bucks, 2 Boosts) |
Enhanced Buck: +28% of selected nominal voltage | ||
Buck mode: +10% of selected nominal voltage | |||
Boost mode: -10% of selected nominal voltage | |||
Enhanced Boost: -25% of selected nominal voltage | |||
Surge Protection | 1KW/ 2KW:416 Joules | 1KW-3KW:430 Joules | |
3KW ~ 4KW:724 Joules | 4KW-6KW:826 Joules | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) | |
DC Voltage | 1KW/2KW:12Vdc | 1KW/2KW/3KW:12Vdc | |
2KW/3KW:24Vdc | 2KW/3KW:24Vdc | ||
3KW/4KW:48Vdc | 3KW/4KW/5KW/6KW:48Vdc | ||
Typical backup time | No Limit | ||
Charging method | Smart pulse charging with two charging modes?EQuick charging when battery | ||
is not fully charged, trickle charging when battery is 90% fully charged. | |||
Maximum charging current | 1000W 12V:35A | 1000W 24V:35A | |
2000W 12V:65A | 2000W 24V:35A | ||
3000W 24V:45A | 4000W 48V:35A | ||
5000W 48V:40A | 6000W 48V:50A | ||
Average charging | Quick charging mode:15.7V-54V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V -52V(adjustable with the remote set-up software) | ||
Protection | Over current protection & Over charging voltage protection (SCR control) | ||
Thermal protection (CPU control) | |||
When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate | |||
Monitoring | Smart monitoring & warning for failed battery or open-circuit battery. | ||
Auto-detection each time when power on or every 6 days. | |||
SOLAR CHARGER | |||
Rating voltage | 12V / 24V / 48V | 12V / 24V / 48V | |
DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc | ||
Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) | ||
24V model : 1000W/2000W (27.0Vdc @ 37A) | |||
48V model : 3KW/5KW/6KW (54Vdc @ 18.5A) | |||
Protection | DC input polarity protection, DC input short circuit protection( when battery is | ||
connected), DC output over current protection | |||
COMMUNICATIONS & MANAGEMENT | |||
Standard Interface port | UPSilon2000 compatible; optional for RS232 . | ||
Optional Interface part | RJ45 (Surge protection), DB9 | ||
Control panel | LCD or LED Selectable | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load (adjustable by using the remote set-up software) | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVORMENT AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001:2000, ISO 14002-2004 | ||
PHYSICAL | |||
Appearance | Size(mm)LxWxH | 570*315*300 | |
Weight(Kg) | 1000W/18.2kg ;2000W/19.5kg ;3000W/23.5kg | ||
Size(mm)LxWxH | 755*319*288 | ||
Weight(Kg) | 4000W/35kg ;5000W/38kg ;6000W/40kg |
Customers Service:
(1)Warranty :
Our product warranty is valid for 12 months after delivery. We undertake to repair any malfunctioned units due to defective components of inadequate workmanship ,but specially expecting any defects resulting from normal wear and tear of improper use of the products.
(2)Lead time:
a.sample orders (1-2pcs)will be delivered from our factory within 7working days .
b.Bulk orders will be delivered from our factory within 25 working days.
(3)shippment :
By sea ,airway , EMS, DHL, FedEx, TNT, UPS or other express.
(4)Payment: T/T (Telegraphic transfer), and Western Union
Contact us:
Must power produce green stable high quality ups,inverter ,solar system,we
light your life,light up the world,we grow up everyday,join us !!