Rated Voltage | MPPT 12/24/48Vdc | ||
Rated charge current (Include load current) | 40/60Amp | ||
Load current | 15Amp | ||
Input voltage range | 15-105Vdc | ||
Max. PV open circuit array voltage | 105Vdc | ||
Overload protection (DC load) | 2.0 * Inom>5s 1.5 * Inom >20s 1.25 * Inom temperature controlled | ||
Typical idle consumption | At idle < 10mA | ||
Bulk charge (Default) | 14.6Vdc | 29.2Vdc | 29.2Vdc |
Floating charge (Default) | 13.4Vdc | 26.8Vdc | 53.6Vdc |
Equalization charge (Default) | 14.0Vdc | 28.0Vdc | 56.0Vdc |
Over charge disconnection | 14.8Vdc | 29.6Vdc | 59.2Vdc |
Over charge recovery | 13.6Vdc | 27.2Vdc | 54.4Vdc |
Over discharge disconnection | 10.8Vdc (default) | 21.6Vdc (default) | 43.2Vdc (default) |
Over discharge reconnection | 12.3Vdc | 24.6Vdc | 49.2Vdc |
Temperature compensation | -13.2mV/ | -26.4mV/ | -52.8mV/ |
Lead acid battery settings | Adjustable | ||
NiCad battery settings | Adjustable | ||
Load control mode | 1. Low Voltage Reconnect (LVR): Adjustable 2. Low Voltage Disconnect (LVD): Automatic disconnection 3. Reconnection: Includes warning flash before disconnect & reconnection |
||
Low voltage reconnect | 12.0-14.0Vdc | 24.0-28.0Vdc | 48.0-56.0Vdc |
Low voltage disconnect | 10.5-12.5Vdc | 21.0-25.0Vdc | 42.0-50.0Vdc |
Ambient temperature | 0-40 (Full load) 40-60 (De-Rating) | ||
Altitude | Operating 5000 m, Non-Operating 16000 m | ||
Protection class | IP21 | ||
Battery temperature sensor | BTS - Optional Remote battery temperature sensor for increased charging precision | ||
Terminal size (fine/single wire) | #8 AWG |
PV inverter battery priority | |||||||
MODEL | 4000w | 5000w | 6000w | ||||
Input Voltage Waveform | Sinusoidal (utility or generator) | ||||||
Nominal Input Voltage | 230Vac | ||||||
Low Line Disconnect | 155Vac±4% | ||||||
High Line Disconnect | 265Vac±4% | ||||||
Max AC Input Voltage | 270Vrms | ||||||
Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | ||||||
Over-Load Protection | Circuit breaker | ||||||
Output Short Circuit Protection | Circuit breaker | ||||||
Efficiency (Line Mode) | >90% | ||||||
Transfer Switch Rating | 30A | ||||||
Transfer Time(Ac to Dc) | 20ms (typical) | ||||||
Output Voltage Waveform | Sine wave | ||||||
Rated Output Power (W) | 4000w | 5000w | 6000w | ||||
Power Factor | 1 | ||||||
Nominal Output Voltage (V) | 230Vac | ||||||
Output Voltage Regulation | ±10% rms | ||||||
Nominal Efficiency | >80% | ||||||
Nominal DC Input Voltage | 24V | ||||||
Nominal Charge Current | 45A/65A | ||||||
Charge Current Regulation | ± 5A | ||||||
Battery initial voltage | 0 -15.7 Vdc /31.4Vdc(can operate with 0V battery) | ||||||
Communication: | RJ11 (Used for factory testing. No customer interface available) | ||||||
Safety Certification | CE(EN60950) | ||||||
EMI Classification | EN50091-2, CLASS A | ||||||
Operating Temperature Range | 0°C to 40°C | ||||||
Storage temperature | -15ºC ~ 60ºC | ||||||
Operation humidity | 5% to 95% | ||||||
Audible Noise | 60dB max | ||||||
Cooling | Forced air, variable speed fan | ||||||
Dimensions (H×D×W) | 765*360*310mm | ||||||
N.W/G.W(Kg) | 4000W/43kg ; 5000W/52kg ; 6000W/52kg |