Guangdong, China
Business Type:
Main Products:
Main Markets:
Europe, Africa
Terms of Payment:
LC, T/T, D/P, Western Union, Small-amount payment
OEM/ODM Availability:
OEM/ODM Service
Sample Available

Pure Sine Wave Inverter, Inverter with Super Charger, Power Inverter manufacturer / supplier in China, offering Must IEC Approved 6kw 24V Power Pump Inverter in Pakistan, Micro Inverter off Grid Solar Power Inverter Hybrid 1800va 1000watt, Must High Frequency 19 Inch Rack Mount Online UPS 1kVA-6kVA and so on.

Gold Member Since 2010
Audited Supplier
Supplier Homepage Products pure sine wave power Inverter Must IEC Approved 6kw 24V Power Pump Inverter in Pakistan

Must IEC Approved 6kw 24V Power Pump Inverter in Pakistan

Get Latest Price
Purchase Qty. / Reference FOB Price
1-9 Pieces US $259
10+ Pieces US $245
Production Capacity: 3000 Pieces / Month
Transport Package: Carton or Wooden Packing
Payment Terms: L/C, T/T, Western Union
Phase: Single
Type: DC/AC Inverters
Power Source: Solar Power
Output Power: >1000W
Nature of Wave String: Sine Wave Inverter
Application: air conditioner

You Might Also Like


Basic Info

Model NO.: EP3000 1-3KW
Certification: SAA, CE, ROHS, ISO9001
Sine Wave: Pure Sine Wave
Power Range: 1000kw to 6000kw
Frequency: Low Frequency
Size: 1-3kw:570*315*300mm;4-6kw:755*319*288mm
Warranty: One Year
Input Voltage: 110VAC/220VAC
Power: 1kw to 6kw
Display: LCD
Color: Black and White
Work Temperqture: -25c-55c
Trademark: must
Specification: CE, ISO9001&14000
Origin: Shenzhen, China
HS Code: 8504403090

Product Description

MUST  Hot 2016 Power Inverter 6KW Power Pump Inverter in Pakistan
Model:EP3000 1-3KW

New power factor corrected (PFC) charging
Available in 1000 and 3000 watt models Utility grade, sine wave power Durable construction for long life under extreme environmental conditions 70 AMP automatic three-stage battery charger (bulk, absorption, and float) Battery equalization with remote temperature sensor for increased performance Low idle current (less than 1 watt) conserves energy when no loads are present Built-in starting control circuits for two- and three-wire generator starting systems.

New digital display shows kilowatts (kW) when inverting and AMPS (A) when charging Better thermal performance allows full output power to 50° C (122° F) without de-rating High surge capacity starts more difficult loads and handles overload conditions reliably Simplified controls with a snap-on cover that protects settings from being accidentally changed.

MODEL115V  Models230V  Models
Power Levels crated at nominal inputs1KW;2KW;3KW;4KW1KW;2KW;3KW;4KW;5KW;6KW
Output Voltage110V/115V/120V Selectable220V/230V/240V Selectable
Voltage WaveformPure Sine wave
Crest Factor3:'1
Output FrequencyAuto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal
(Synchronized to Mains)
Regulation (Nominal)±20% typical of nominal voltage
Regulation±3% of selected output voltage (adjustable with the
(Battery mode)remote set-up software)
Transfer timeBlackout 3ms typical,Brownout 1ms typical,Battery mode to Normal mode:1ms typical
Over current protectionOver load alarm level 100% ~ 120%
Over load shutdown level 120% ~ 190%
(Adjustable by using the remote set-up software)
Nominal Voltage110V/115V/120V Selectable220V/230V/240V Selectable
Input Frequency47Hz ~ 65Hz, 50/60Hz auto-sensing
Efficiency (Normal mode)99%
Noise FilteringFull time EMI/RFI filtering
Over current protectionRe-settable over current protector:1000W~4KWAC Fuse1000VA/2000VA,Re-settable over current protector:1000W~6KW
Voltage Range85V ~ 145V185V ~ 265V
AVR Range
(2 Bucks, 2 Boosts)
Enhanced Buck: +28% of selected nominal voltage
Buck mode: +10% of selected nominal voltage
Boost mode: -10% of selected nominal voltage
Enhanced Boost: -25% of selected nominal voltage
Surge Protection1KW/ 2KW:416 Joules1KW-3KW:430 Joules
3KW ~ 4KW:724 Joules4KW-6KW:826 Joules
Battery typeLead-Acid 50Ah~500Ah (Recommended)Lead-Acid 50Ah~500Ah (Recommended)
DC Voltage1KW/2KW:12Vdc1KW/2KW/3KW:12Vdc
Typical backup timeNo Limit
Charging methodSmart pulse charging with two charging modes?EQuick charging when battery
is not fully charged, trickle charging when battery is 90% fully charged.
Maximum charging current1000W 12V:35A1000W 24V:35A
2000W 12V:65A2000W 24V:35A
3000W 24V:45A4000W 48V:35A
5000W 48V:40A6000W 48V:50A
Average chargingQuick charging mode:15.7V-54V maximum.
voltage for each batteryTrickle charging mode:13.5V -52V(adjustable with the remote set-up software)
ProtectionOver current protection & Over charging voltage protection (SCR control)
Thermal protection (CPU control)
When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate
MonitoringSmart monitoring & warning for failed battery or open-circuit battery.
Auto-detection each time when power on or every 6 days.
SOLAR CHARGER                                                                                                                                        
Rating voltage12V / 24V / 48V12V / 24V / 48V
DC input range12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc
Charging methodConstant voltage with current limiting by PWM control
Charging voltage12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc
Power rating12V model : 1000W/2000W (13.5Vdc @ 37A)
24V model : 1000W/2000W (27.0Vdc @ 37A)
48V model : 3KW/5KW/6KW (54Vdc @ 18.5A)
ProtectionDC input polarity protection, DC input short circuit protection( when battery is
connected), DC output over current protection
Standard Interface portUPSilon2000 compatible; optional for RS232 .
Optional Interface partRJ45 (Surge protection), DB9
Control panelLCD or LED Selectable
Audible alarmAlarm on battery:Low battery & Battery over voltage
Alarm on abnormal operation:Over load, Short-circuit, & Over heat
Green mode function1% to 14% of full load (adjustable by using the remote set-up software)
(Auto-shut-off in blackout)The default setting is OFF.
Cooling fan controlAuto on / off, controlled by temperature & operation mode
ENVORMENT AND SAFETY                                                                                                                           
Operating TemperatureUp to 1500 meters:0°C to 40°C (32°Fto 104°F)
Transit/storage Temp.-15°C to 55(5°F to 131°F)
Relative Humidity5 - 95% non condensing
Operating Altitude0 ~ 3000 meters
Quality control systemISO 9001:2000, ISO 14002-2004
Weight(Kg)1000W/18.2kg ;2000W/19.5kg ;3000W/23.5kg
Weight(Kg)4000W/35kg ;5000W/38kg ;6000W/40kg

Contact US:
--------Want to know more about our company?
--------Want to know more about our products? Want to know more about the Price, packing, Shipping and any discount? Dear Friend, Do not Hesitate. Leave a Inquiry! ! ! ! : -

Why Always Must Power???
1.Professional--Over 10 years Professional Power System Producing Experience
3.Hi-tech--Two Advanced R&D Team
4.Certifications--Applied with CE, ISO 9001, Soncap,IEC etc
5.Quality guarantee--One year warranty
Samples and OEM
Samples are Available for Testing and Market Test. OEM is welcomed for us.
1-Year Warranty on MUST POWER Products

MUST POWER provides a 1-year limited warranty ("Warranty") against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers including inverter12v 24v 48V, Solar charge controllers ("Product").
Guides and After-service Consultancy

Must Power Team will offer these guides below.
  A. Need a Accessory
  B. Products Repair
  C. Power Problems to Solve
 D. Power Protection Solutions, etc.

24 Hours After-service consultancy just for you and to make your problems to solve easily.

We have a aftersales office in Pakistan Lahore, then we will open more and more office all over the world.
Welcome to contact me freely.
MUST Power Limited
Ada Ma
+86-132 5953 2991

Want to know more information??Dear Friend, Let's Inquiry NOW!!!!!

Send your message to this supplier

avatar Mr. Shoaib

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now