220v/110v ture Online UPS high frequency 6kVA 10kVA
Main Feature:
1. Ture online ups 6kva,10kva European design: 1 phase 220vac,230vac,240vac, 1 Ph + N + G
2. Ture online ups 6kva,10kva American standard output electrical wiring 110v+110v
for secure power solution of medical equipment eg. medical X-ray explosure machine
Galvanic Isolation Output Transformer internal configured
isolating pure sine wave output power from complicate Ac input network in case of heavier
noise interference, harmonic distortion;
isolating output neutral from ground line in case of unexpected electric shocks
3. ture online ups 6kva,10kva provides high reliability power solution from an advanced, dsp-based,
full-digitalized micro-processor control tech;
4. ture online ups better ultilize Ac input power with a PFC rectifier of higher input P.F. 0.97
5. ture online ups provides high stability power solution from an advanced,transformer-less, dsp-based
IGBT inverter
stability also reflects in pure sine wave output power from IGBT inverter
stability also reflects in zero transfer time from Ac-mode to Battery-mode when Ac blackouts
higher inverter efficiency and power-saving
0.85 on battery-mode, 0.9 on Ac-mode
6. ture online ups provide uninterrupted power supply from internal or external battery design of
192vdc or 240vdc
7. ture online ups finish communication, network monitor and power management conveniently and
easily from thorough communication interfaces:
standard RS232, optional USB, AS400 expansion card, SNMP network monitor, power management
tool, protocol.
8. ture online ups provide secure power solution from internal configured Galvanic Isolation Output
transformer design
Online ups with isolation transformer
Ture online ups, online ups power, online ups power supply, online ups with isolation transformer,
online high frequency ups, online ups, high frequency ups, high frequency online ups, rack online ups,
Photos:
EH5000 Series H6KVA/10KVA UPS |
ture online ups |
|
H6KVA |
H10KVA |
H6KS |
H10KS |
Rated Power |
Volt-Amps/Watts |
6KVA/4.8KW |
10KVA/8KW |
6KVA/4.8KW |
10KVA/8KW |
Input |
Nominal Voltage |
220VAC |
Voltage Range |
145 ~ 275VAC (46~54Hz) |
Output |
Voltage |
220VAC |
Frequency |
Synchronized 46~54Hz(Line mode) |
50Hz ± 0.1% (Battery mode) |
Wave Form |
Sine wave |
Voltage Distortion |
3% under linear load |
Overload Capability |
105%~130% for 10 min. |
Current Crest Ratio |
3:01 |
Battery & Charger |
Type |
Valve regulated, Sealed, Lead-Acid |
External Battery Bank |
Nominal Voltage |
192VDC or 240vdc |
Backup time (Full load) |
5 min |
5 min |
Depends on the external battery capacity |
Transfer Time |
0 ms |
LED/LCD status |
Load level / Battery level, Battery, Utility Power, Inverter, Bypass, Overload, Fault |
Audible Alarms |
On battery mode, Battery low, Overload, Fault |
Communications Interface |
USB/RS-232 Serial Interface (DB-9), Intelligent Slot |
Parallel Port |
Availability of up to three units in parallel for power redundancy and load sharing |
Physical |
N.W. (Kg) |
57 |
67.5 |
18 |
21.5 |
G.W. |
68 |
78.5 |
23 |
27.5 |
Body size (w *d* h) |
248 x 500 x 616 mm |
240 x 500 x 460 |
Packing size(w *d* h) |
390*680*834mm |
390*595*578mm |