Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | ISO9001, CE, SAA |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | 115V Models | 230V Models | |
OUTPUT | |||
Power Levels crated at nominal inputs | 1KW;2KW;3KW;4KW | 1KW;2KW;3KW;4KW;5KW;6KW | |
Output Voltage | 110V/115V/120V Selectable | 220V/230V/240V Selectable | |
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:'1 | ||
Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
(Synchronized to Mains) | |||
Regulation (Nominal) | ±20% typical of nominal voltage | ||
Regulation | ±3% of selected output voltage (adjustable with the | ||
(Battery mode) | remote set-up software) | ||
Transfer time | Blackout 3ms typical,Brownout 1ms typical,Battery mode to Normal mode:1ms typical | ||
Over current protection | Over load alarm level 100% ~ 120% | ||
Over load shutdown level 120% ~ 190% | |||
(Adjustable by using the remote set-up software) | |||
INPUT | |||
Nominal Voltage | 110V/115V/120V Selectable | 220V/230V/240V Selectable | |
Input Frequency | 47Hz ~ 65Hz, 50/60Hz auto-sensing | ||
Efficiency (Normal mode) | 99% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Over current protection | Re-settable over current protector:1000W~4KW | AC Fuse1000VA/2000VA,Re-settable over current protector:1000W~6KW | |
Voltage Range | 85V ~ 145V | 185V ~ 265V | |
AVR Range (2 Bucks, 2 Boosts) |
Enhanced Buck: +28% of selected nominal voltage | ||
Buck mode: +10% of selected nominal voltage | |||
Boost mode: -10% of selected nominal voltage | |||
Enhanced Boost: -25% of selected nominal voltage | |||
Surge Protection | 1KW/ 2KW:416 Joules | 1KW-3KW:430 Joules | |
3KW ~ 4KW:724 Joules | 4KW-6KW:826 Joules | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) | |
DC Voltage | 1KW/2KW:12Vdc | 1KW/2KW/3KW:12Vdc | |
2KW/3KW:24Vdc | 2KW/3KW:24Vdc | ||
3KW/4KW:48Vdc | 3KW/4KW/5KW/6KW:48Vdc | ||
Typical backup time | No Limit | ||
Charging method | Smart pulse charging with two charging modes?EQuick charging when battery | ||
is not fully charged, trickle charging when battery is 90% fully charged. | |||
Maximum charging current | 1000W 12V:35A | 1000W 24V:35A | |
2000W 12V:65A | 2000W 24V:35A | ||
3000W 24V:45A | 4000W 48V:35A | ||
5000W 48V:40A | 6000W 48V:50A | ||
Average charging | Quick charging mode:15.7V-54V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V -52V(adjustable with the remote set-up software) | ||
Protection | Over current protection & Over charging voltage protection (SCR control) | ||
Thermal protection (CPU control) | |||
When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate | |||
Monitoring | Smart monitoring & warning for failed battery or open-circuit battery. | ||
Auto-detection each time when power on or every 6 days. | |||
SOLAR CHARGER | |||
Rating voltage | 12V / 24V / 48V | 12V / 24V / 48V | |
DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc | ||
Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) | ||
24V model : 1000W/2000W (27.0Vdc @ 37A) | |||
48V model : 3KW/5KW/6KW (54Vdc @ 18.5A) | |||
Protection | DC input polarity protection, DC input short circuit protection( when battery is | ||
connected), DC output over current protection | |||
COMMUNICATIONS & MANAGEMENT | |||
Standard Interface port | UPSilon2000 compatible; optional for RS232 . | ||
Optional Interface part | RJ45 (Surge protection), DB9 | ||
Control panel | LCD or LED Selectable | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load (adjustable by using the remote set-up software) | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVORMENT AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001:2000, ISO 14002-2004 | ||
PHYSICAL | |||
Appearance | Size(mm)LxWxH | 570*315*300 | |
Weight(Kg) | 1000W/18.2kg ;2000W/19.5kg ;3000W/23.5kg | ||
Size(mm)LxWxH | 755*319*288 | ||
Weight(Kg) | 4000W/35kg ;5000W/38kg ;6000W/40kg |