Must Power Range 1-12kw LCD LED Display MPPT Solar Inverter

Nature of Source Flow: Active Inverter
Phase: Single
Output Power: 1000-3000W
Certification: SAA, CE, ROHS, ISO9001
Brand: Must/OEM
Type: DC/AC Inverters
Customization:

Contact Supplier

Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Other

Basic Info.

Model NO.
PV3500 1-12KW
Power Source
Solar Power
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Sine Wave Inverter
Item
5kw 48V Solar Inverter
Solar Controller
MPPT40
AC Input
96-132VAC 155-280VAC
Frequency Range
50Hz/60Hz
Waveform
Pure Sine Wave
Inverter Efficiency
>88%
Display
LED+LCD
Power Factor
0.8
Audible Noise
60dB Max
Storage Temperature
-15°c to 60°c
Application
Air Conditioner
Transport Package
Carton Packing
Specification
260*460*185mm
Trademark
MUST
Origin
China
HS Code
8504403090
Production Capacity
1000PCS/Month

Product Description

MUST Power Range 1-12KW LCD LED Display MPPT Solar Inverter
Model:PV3000 1-6KW
Features
Low Frequency Solar Inverter

Maximum power point Tracking (MPPT) function.
It is an electronic system that operates the photovoltaic(PV) modules in a manner that allows the modules to produce all the power they are capable of. The solar mate charge controller is a microprocessor-based system designed to implement the MPPT. It can increase charge current up to 30% or more compared to traditional charge controllers.


AC/Battery Priority

Our inverter is designed AC priority by default. This means, when AC input is present, the battery will be charged first.
When you choose battery priority(Battery type selector on 7-9), then inverter will invert from battery despite the AC input. Only when the battery voltage reaches low voltage alarm point will be inverter transfer to AC input, charge battery and switch back to battery when the battery is fully charged. This function is mainly for wind/'solar systems using utility power as back up. 

Specifications
 
Hybrid Inverter(PV3000 series)
MPPT solar controller function
Rated Voltage 12/24V DC
Rated Charge current  40A
Load current 15A
Input voltage range 15-55V DC
Max. PV open circuit array voltage 55V DC
Typical idle consumption At idle< 10mA
Overload protection(DC load) 2.0*Inom>5s                            1.5*Inom>20s                       1.25*Inom temperature controlled
Bulk charge 14.6V(default) 29.2V(default)
Floating charge 13.4V(default) 26.8V(default)
Equalization charge 14.0V(default) 28.0V(default)
Over charge disconnection  14.8V 29.6V
Over charge recovery 13.6V 27.2V
Over discharge disconnection 10.8V(default) 21.6V(default)
Over discharge reconnection 12.3V 24.6V
Temperature compensation 13.2mV/C 26.4mV/C
Lead acid battery settings Adjustable
NiCad battery settings Adjustable
Load control mode  1.Low Voltage Reconnect(LVR):Adjustable  2.Low Voltage Disconnect(LVD):Automatic  disconnection                 3.Reconnection:Includes warning flash before disconnect and reconnection
Low voltage reconnect 12.0-14.0Vdc 24.0-28.0Vdc
low voltage disconnet 10.5-12.5Vdc 21.0-25.0Vdc
Ambient temperature 0-40 degree(full load)  40-60 degree (de-rating)
Altitude Operating5000m,Non-Operating 16000m
Protection class IP21
Battery temperature sensor BTS-optional remote battery temperature sensor for increased charging precision
Terminal size(fine/single wire) #8 AWG

Detailed Picture
Solar System Connection


Payment & Shipping & Sample
1. Payment: T/T (Telegraphic transfer), and Western Union
2. Delivery time: 7 workdays for sample; 20-25 workdays for mass order
3. Shipping: DHL, FEDEX, UPS, EMS, Airway and By Sea

**Welcome Sample Order to test quality firstly**


Warranty :
Our product warranty is valid for 12 months after delivery. We undertake to repair any malfunctioned units due to defective components of inadequate workmanship ,but specially expecting any defects resulting from normal wear and tear of improper use of the products.
Guides and After-service Consultancy
Must Power Team will offer these guides below.
A. Need a Accessory
B. Products Repair
C. Power Problems to Solve
D. Power Protection Solutions, etc.
Want to know more about our Company, Products, Price, Packing, Shipping and
any discount? Let's Inquiry with Ada NOW !!!!!

 
MUST Power Limited
Zoey Zou
 

Send your message to this supplier

*From:
*To:
avatar Ms. Tina Yuan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Other
Management System Certification
ISO 9001, ISO 14001, SA 8000
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, OA