Customization: | Available |
---|---|
Certification: | ISO9001, CE, SAA |
Output Power: | >1000W |
Still deciding? Get samples of US$ 180/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | ||||||||||
(EP3000) | 1012E | 1024E | 2012E | 2024E | 3012E | 3024E | 3048E | 4048E | 5048E | 6048E |
Line Mode Specifications | ||||||||||
Input Voltage Waveform | Sinusoidal (utility or generator) | |||||||||
Nominal Input Voltage | 230Vac (120vac selectable) | |||||||||
Low Line Disconnect | 155Vac± 4% / 96vac± 4% | |||||||||
Low Line Re-connect |
164Vac ± 4% /100vac± 4% | |||||||||
High Line Disconnect | 272Vac± 4% / 132vac± 4% | |||||||||
High Line Re-connect |
265Vac± 4% / 127vac± 4% | |||||||||
Max AC Input Voltage | 270Vrms /140vrms | |||||||||
Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | |||||||||
Low Line Frequency Re-connect |
58+0.3Hz for 60Hz; 48+0.3Hz for 50Hz; | |||||||||
Low Line Frequency Disconnect | 57+0.3Hz for 60Hz; 47+0.3Hz for 50Hz; | |||||||||
High Line Frequency Re-connect |
64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; | |||||||||
High Line Frequency Disconnect | ||||||||||
65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; | ||||||||||
Output Voltage Waveform | As same as Input Waveform | |||||||||
Over-Load Protection(SMPSload) | Circuit breaker | |||||||||
Output Short Circuit Protection | Circuit breaker | |||||||||
Efficiency (Line Mode) |
> 95% | |||||||||
Transfer Switch Rating | 30A/ 40A | |||||||||
Transfer Time (Ac to Dc) |
10ms (typical) | |||||||||
Transfer Time (Dc to Ac) |
10ms (typical) | |||||||||
Pass through without Battery | Yes | |||||||||
Max Bypass Overload Current | 30A | |||||||||
Invert Mode Specifications | ||||||||||
Output Voltage Waveform | Sine wave | |||||||||
Rated Output Power(VA) | 1KVA | 2KVA | 3KVA | 4KVA | 5KVA | 6KVA | ||||
Rated Output Power(W) | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | ||||
Power Factor | 0~1.0 | |||||||||
Nominal Output Voltage(V) | 230Vac / 120VAC | |||||||||
Nominal Output Frequency(Hz) | 50Hz ± 0.3Hz | |||||||||
Auto tracking Main Frequency(Hz) | Yes (Following Main first connection)50Hz @48-54Hz; 60Hz @58-64Hz | |||||||||
Output Voltage Regulation | ± 10% rms | |||||||||
Nominal Efficiency | > 80% | |||||||||
Surge rating(10s) |
3KVA | 6KVA | 9KVA | 12KVA | 15KVA | 18KVA | ||||
Capable of starting electric motor |
1 HP | 1 HP | 2 HP | 3 HP | ||||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||||
Bypass Breaker Size | 30A | 30A | 30A | 30A | 30A | 35A | 50A | |||
Nominal DC Input Voltage | 12V | 24V | 12V | 24V | 12V | 24V | 48V | 48V | 48V | |
Min DC start voltage |
10V/20V/40V | |||||||||
Power saver | Load ≤ 25W (Enabled on " P/S auto" setting of Remote control) | |||||||||
Charge Mode Specifications | ||||||||||
Nominal Input Voltage | 230Vac /120VAC | |||||||||
Input Voltage Range | 155-265Vac / 96-127VAC | |||||||||
Nominal Output Voltage | According to the battery type | |||||||||
Nominal Charge Current | 35A | 35A | 70A | 35A | 35A | 35A | 35A | 40A | 50A | |
Charge Current Regulation | ± 5Adc | |||||||||
Battery initial voltage | 0- 15.7 Vdc (can operate with 0V battery) | |||||||||
Charger Short Circuit Protection | Circuit breaker | |||||||||
Over Charge Protection | Bat. V ≥ 15.7Vdc/31.4Vdc, beeps 0.5s every 1s & fault after 60s | |||||||||
Others | ||||||||||
Inverter gift box Size(mm) | 580x315x300 | 755x319x288 | ||||||||
Net weight( kg) | 18 | 20 | 24 | 35 | 46 | |||||
Gross weight(kg) | 20 | 22 | 26 | 39 | 48 |