Must pH3000 3000W Grid Tie Inverter with MPPT60A Solar Charger Power System

Product Details
Customization: Available
Nature of Source Flow: Active Inverter
Phase: Single
Gold Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001, SA 8000
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, OA
  • Must pH3000 3000W Grid Tie Inverter with MPPT60A Solar Charger Power System
  • Must pH3000 3000W Grid Tie Inverter with MPPT60A Solar Charger Power System
Find Similar Products

Basic Info.

Model NO.
PH3000
Output Power
2000-6000W
Certification
CE, ISO9001
Brand
Must
Type
DC/AC Inverters
Power Source
Electric Power or Solar Power
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Sine Wave Inverter
Input Voltage
48VDC
Output Voltage
220V/230VAC
Output Voltage Waveform
Pure Sine Wave
PV Open Circuit Voltage
145
Output
Pure Sine Wave
Power Factor
Grid Discharge 99%, Grid Charge 99%
Mount
Wall Mounted
Display
LCD
Selectable Model
2000W, 3000W, 4000W
Sepcfication
337*462*183
Application
air conditioner
Transport Package
Carton Packing/Giftbox/Woolen Packing
Specification
337*462*183
Trademark
MUST
Origin
China
HS Code
8504403090
Production Capacity
1000PCS/Month

Product Description

 Must pH3000 3000W Grid Tie Inverter with MPPT60A Solar Charger power  system

1.on grid with inverter with energy storage
2. Combining solar system,AC utility, and battery power source to supply continuous power
3. Multiple operations: Grid tie,Off Grid, and grid-tie with backup
4. Pure sine wave output
5. LCD status display


Popular solar UPS for homes
It is an electronic system that operates the photovoltaic(PV) modules in a manner that allows the modules to produce all the power they are capable of. The solar mate charge controller is a microprocessor-based system designed to implement the MPPT. It can increase charge current up to 30% or more compared to traditional charge controllers.

AC or Battery Priority
Our inverter is designed AC priority by default. This means, when AC input is present, the battery will be charged first.
When you choose battery priority(Battery type selector on 7-9), then inverter will invert from battery despite the AC input. Only when the battery voltage reaches low voltage alarm point will be inverter transfer to AC input, charge battery and switch back to battery when the battery is fully charged. This function is mainly for wind/'solar systems using utility power as back up

Payment & Shipping & Sample
1. Payment: T/T (Telegraphic transfer), and Western Union
2. Shipping: DHL, FedEx, UPS, EMS, Airway and By Sea

Specification:

MODEL
PH30-2K PH30-3K PH30-4K PH30-5K PH30-6K
Default Battery System Voltage 48 VDC
SOLAR CHARGER
&
AC CHARGER
PV Open Circuit Voltage(VDC) 145 VDC
Max PV Input Power(W) 2600W 3200W 3200W 6400W 6400W
Max Solar Charging Current(A) 45A 60A 120A
Max AC Charging Current(A) 40A 60A 80A 100A 120A
Battery Rated input voltage(VDC) 48 VDC
Allowed input DC voltage scope(VDC) 40 VDC -- 62 VDC
LV alarm point(VDC) 42 VDC
OV alarm point(VDC) 60VDC
AC Output Rated capacity(VA) 2500VA 3750VA 5000VA 6250VA 7500VA
Rated output power(W) 2000W 3000W 4000W 5000W 6000W
Rated output voltage and frequency (Vac/Hz) 230Vac / 50Hz
Rated output current(A) 8.7A 13A 17.4A 21.7A 26A
Output voltage precision(Vac) 230 Vac±1%
Output frequency precision(Hz) 50 Hz±0.1%
Rate of wave distortion(THD)
(Linearity loads)
Off grid≤2%
Grid discharge ≤3%
Grid charge ≤3%
Dynamic response speed(0←→100%) 20ms
Power factor Grid discharge 99.9% & Grid charge 99.9%
Overload capability 110%,30 minutes
125%,1 minutes
150%,30 seconds
200%,10 seconds
Short circuit 5s
Grid / Off grid change time <10ms
Output wave sine
Inverting efficiency 80% resistive loads ≥92% ≥93%
Standby Power Consumption <2W
AC Input AC Input maximum of current(A) 17.4A 26A 34.8A 43.4A 52A
AC Input voltage scope(Vac) 184Vac ~ 253Vac
AC Input frequency scope(Hz) 47.5Hz ~ 51.5Hz
Display

Protection Function
LED indication Systematic operation, indication of charge and discharge, indication of fault
LCD display output voltage, output current, grid voltage, grid current, voltage of storage battery, load power, chart of capacity
Protection Function Input LV protection
Input OV protection
Output overload protection
Output Short Circuit Protection
Mechanical Specifications Mounting Wall mount
W*H* D(mm)/G.W(kg) 337*462*183mm/25kg 337*462*183mm/29.5kg 370*462*183mm/35kg 370*537*183mm/47kg 370*537*183mm/47kg
Other Communication terminal RS485 / CAN bus
Operation Temperature Range -20ºC ~ +50ºC
Environmental Protection Rating Indoor(IP20)
Ambient humidity 0 ~ 90% relative humidity(non-condensing)
Altitude ≤3000m

Samples and OEM
Samples are Available for Testing and Market Test. OEM is welcomed for us.
1-Year Warranty on MUST POWER Products
MUST POWER provides a 1-year limited warranty ("Warranty") against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers including inverter12v 24v 48V, Solar charge controllers ("Product").
Guides and After-service Consultancy
Must Power Team will offer these guides below.
  A. Need a Accessory
  B. Products Repair
  C. Power Problems to Solve
 D. Power Protection Solutions, etc.
24 Hours After-service consultancy just for you and to make your problems to solve easily.

Want to know more about our Company, Products, Price, Packing, Shipping andany discount? Let's Inquiry NOW !!!!! 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier