Certification: ISO9001, RoHS, CE
Output Power: >1000W
Grid Type: off-Grid Inverter
Output Type: Single
Nature of Wave String: Sine Wave Inverter
Type: DC/AC Inverters
Samples:
US$ 150/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Other

Basic Info.

Model NO.
EP3000
Transport Package
Carton or Wooden Packing
Specification
CE, SGS, ISO9001, soncap
Trademark
must
Origin
China
HS Code
8504403090
Production Capacity
8000 PCS/Month

Product Description

Main features:
1. Solar pure sine wave inverter 1kw to 6kw with super charger
2. CE/SONCAP
3. Pure sine wave
4. Pure copper transformer
5.120/220V optional

Details:
A. Durable construction for long life under extreme environmental conditions
B. Low idle current (less than 1 watt) conserves energy when no loads are present
C. Inverter has soft start capability for starting heavy loads
D. Built-in starting control circuits for two- and three-wire generator starting systems in inverter
E. Simplified controls in inverter with a snap-on cover that protects settings from being accidentally changed in inverter
F. Better thermal performance allows full output power to 50° C (122° F) without de-rating

G. High surge capacity inverter starts more difficult loads and handles overload conditions reliably
H. Durable powder coated, corrosion resistant steel chassis
I. New digital display (LCD model available) inverter shows kilowatts (kW) when inverting and AMPS (A) when charging, plus incorporates a robust ON/OFF switch and status indicators
J. 70-amp automatic three-stage battery charger in inverter (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance

Protection Features
A. Battery over voltage and under voltage protection
B. Over temperature protecton
C. Automatic overload protection
D. Short circuit protection

Pure Sine Wave 12VDC 24VDC 48VDC DC to AC Power Star Inverter
MODEL                                                                              
(EP3000) 1012E 1024E 2012E 2024E 3012E 3024E 3048E 4048E 5048E 6048E
Line Mode Specifications
Input Voltage Waveform Sinusoidal (utility or generator)
Nominal Input Voltage 230Vac (120vac selectable)
Low Line Disconnect 155Vac± 4% / 96vac± 4%

Low Line

Re-connect
164Vac ± 4% /100vac± 4%
High Line Disconnect 272Vac± 4% /  132vac± 4%

High Line

Re-connect
265Vac± 4% / 127vac± 4%
Max AC Input Voltage 270Vrms /140vrms
Nominal Input Frequency 50Hz/ 60Hz  (Auto detection)

Low Line Frequency

Re-connect
58+0.3Hz for 60Hz; 48+0.3Hz for 50Hz;
Low Line Frequency Disconnect 57+0.3Hz for 60Hz; 47+0.3Hz for 50Hz;

High Line Frequency

Re-connect
64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz;
High Line Frequency Disconnect  
65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz;
Output Voltage Waveform As same as Input Waveform
Over-Load Protection(SMPSload) Circuit breaker
Output Short Circuit Protection Circuit breaker

Efficiency

(Line Mode)
> 95%
Transfer Switch Rating 30A/ 40A

Transfer Time

(Ac to Dc)
10ms (typical)

Transfer Time

(Dc to Ac)
10ms (typical)
Pass through without Battery Yes
Max Bypass Overload Current 30A
Invert Mode Specifications
Output Voltage Waveform Sine wave
Rated Output Power(VA) 1KVA 2KVA 3KVA 4KVA 5KVA 6KVA
Rated Output Power(W) 1KW 2KW 3KW 4KW 5KW 6KW
Power Factor 0~1.0
Nominal Output Voltage(V) 230Vac / 120VAC
Nominal Output Frequency(Hz) 50Hz ± 0.3Hz
Auto tracking Main Frequency(Hz) Yes (Following Main first connection)50Hz @48-54Hz; 60Hz @58-64Hz
Output Voltage Regulation ± 10% rms
Nominal Efficiency > 80%

Surge rating(10s)
3KVA 6KVA 9KVA 12KVA 15KVA 18KVA

Capable of

starting electric motor
1 HP 1 HP 2  HP 3  HP
Output Short Circuit Protection Current limit (Fault after 10s)
Bypass Breaker Size 30A 30A 30A 30A 30A 35A 50A
Nominal DC Input Voltage 12V 24V 12V 24V 12V 24V 48V 48V 48V

Min DC start

voltage
10V/20V/40V
Power saver Load ≤ 25W (Enabled on " P/S auto" setting of Remote control)
Charge Mode Specifications
Nominal Input Voltage 230Vac /120VAC
Input Voltage Range 155-265Vac / 96-127VAC
Nominal Output Voltage According to the battery type
Nominal Charge Current 35A 35A 70A 35A 35A 35A 35A 40A 50A
Charge Current Regulation ± 5Adc
Battery initial voltage 0- 15.7 Vdc (can operate with 0V battery)
Charger Short Circuit Protection Circuit breaker
Over Charge Protection Bat. V ≥ 15.7Vdc/31.4Vdc, beeps 0.5s every 1s & fault after 60s
Others
Inverter gift box Size(mm) 580x315x300 755x319x288
Net weight( kg) 18 20 24 35 46
Gross weight(kg) 20 22 26 39 48
Pure Sine Wave 12VDC 24VDC 48VDC DC to AC Power Star InverterPure Sine Wave 12VDC 24VDC 48VDC DC to AC Power Star InverterPure Sine Wave 12VDC 24VDC 48VDC DC to AC Power Star InverterPure Sine Wave 12VDC 24VDC 48VDC DC to AC Power Star InverterPure Sine Wave 12VDC 24VDC 48VDC DC to AC Power Star Inverter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Other
Management System Certification
ISO 9001, ISO 14001, SA 8000
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, OA