• off Grid Solar Inverter with MPPT and Charger
  • off Grid Solar Inverter with MPPT and Charger
  • off Grid Solar Inverter with MPPT and Charger
  • off Grid Solar Inverter with MPPT and Charger
  • off Grid Solar Inverter with MPPT and Charger
  • off Grid Solar Inverter with MPPT and Charger

off Grid Solar Inverter with MPPT and Charger

Nature of Source Flow: Pure Sine Wave Inverter
Phase: Single
Output Power: >1000W
Certification: CE, ISO9001
Brand: Must
Power Source: Solar Power
Customization:

Contact Supplier

Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Other

Basic Info.

Model NO.
PV1800
Circuit Topologies
Solar Inverter
Place of Origin
China, Mainland
Power Range
1.25kVA-5kVA
Powerful Charge Rate
Max 65AMP
Inbuilt
Pure Copper Transformer
Pure Sine Wave
Output
LED+LCD
Display
MPPT Solar Charge Controller
in-Built
MPPT Efficiency
Max 98%
50Hz/60Hz
Automatic Sensing
12V/24V/48V
Input Range
Transport Package
Carton Packing
Specification
CE, ISO
Trademark
MUST
Origin
Shenzhen, China
HS Code
8504403090
Production Capacity
5000PCS/Month

Product Description

Solar Power Inverter 4KW 48VDC in Hot Sales

-------Must Power Limited was established in 1998, with the headquarter in Hong Kong, which is a professional Hi-tech enterprise specializes in the research, development and manufacturing of Uninterruptible Power Supply (UPS), power inverter, solar power inverter.

--------Our comprehensive product lines include: Offline UPS, line interactive UPS, online UPS, power inverter, solar inverter, solar controller. Most products with CE, SONCAP certificate and IS9001 quality certificate. We are one of the authorized suppliers for China Government.

--------Must power with an excellent R & D team formed by over 30 engineers, and together 10, 000 square meter in-house manufacturing facilities in Shenzhen city, Guangdong, China.
Our main markets are Africa, Middle East as Ukraine, Italy, Kenya, South Africa, Nigeria, Pakistan etc.
off Grid Solar Inverter with MPPT and Charger

Brief description
Solar PV inverters is an electronic system that operates the photovoltaic(PV) modules in a manner that allows the modules to produce all the power they are capable of. The solar mate charge controller is a microprocessor-based system designed to implement the MPPT. It can increase charge current up to 30% or more compared to traditional charge controllers.
*power range 5kVA-15kVA
*24V/48VDC input voltage
*powerful charge rate up to 100AMP
*inbuilt pure copper transformer
*pure sine wave output
*LED+LCD display
*MPPT solar charge controller 40A 45A 60A
*MPPT efficency max 98%
*50/60Hz automatic sensing
*RS232 with free CD
*battery priority function
*automatically send signal to start generator
*DC start&automatic self-diagnostic function
*high efficiency design&"power saving mode"to conserve energy
Solar inverter 4kw

PV1800 series Solar Inverter Spec.:
RATED POWER 1000VA / 800W 2000VA/
1600W
3000VA / 2400W 4000VA / 3200W 5000VA / 4000W
INPUT
Voltage 230 VAC
Selectable Voltage Range 170-280 VAC (For Personal Computers) ; 90-280 VAC (For Home Appliances)
Frequency Range 50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation 
(Batt. Mode)
230 VAC ± 5%
Surge Power 2000VA 4000VA 6000VA 8000VA 10000VA
Efficiency (Peak) 90% 93%
Transfer Time 10 ms (For Personal Computers) ; 20 ms (For Home Appliances)
Waveform Pure sine wave
BATTERY
Battery Voltage 12 VDC 24 VDC 48 VDC
Floating Charge Voltage 13.5 VDC 27 VDC 54 VDC
Overcharge Protection 15 VDC 30 VDC 60 VDC
Maximum Charge Current 10 A or 20 A 20 A or 30 A 20 A or 30 A
SOLAR CHARGER (OPTION)
Charging Current 50 A
Maximum PV Array Open Circuit Voltage 30 VDC 60 VDC 90 VDC
Standby power Consumption 1 W 2 W 2 W
PHYSICAL
Dimension, D x W x H (mm) 95 x 240 x 316 100 x 272 x 355 120 x 295 x 468
Net Weight (kgs) 5.0 6.4 6.9 9.8 9.8
OPERATING ENVIRONMENT
Humidity 5% to 95% Relative Humidity(Non-condensing)
Operating Temperature 0°C - 55°C
Storage Temperature -15°C - 60°C

Special function: Battery Priority
When you choose battery priority(Battery type selector on 7-9), then inverter will invert from battery despite the AC input. Only when the battery voltage reaches low voltage alarm point will be inverter transfer to AC input, charge battery and switch back to battery when the battery is fully charged. This function is mainly for wind/'solar systems using utility power as back up.

--------Payment & Shipping & Sample
1. Payment: T/T (Telegraphic transfer), and Western Union
2. Shipping: DHL, FedEx, UPS, EMS, Airway and By Sea

--------Want to know more about our company?
--------Want to know more about our products? Want to know more about the Price, packing, Shipping and any discount? Dear Friend, Do not Hesitate. Leave a Inquiry! ! ! ! : -

Contact Person

MUST POWER LIMITED
Kunny
Tel: +86 136 327 52624

Send your message to this supplier

*From:
*To:
avatar Ms. Tina Yuan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Other
Management System Certification
ISO 9001, ISO 14001, SA 8000
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, OA